On the workbench, Clark prepares a 16-cell WirenTech 48V 100Ah rack-mount battery for an off-grid electrical setup before heading back out to S/V Temptress in December. Like any multi-cell lithium assembly, individual cells arrive from the manufacturer with varying states of charge and unequal capacity headroom. Without equalizing those disparities early, the highest cell encounters its upper voltage ceiling prematurely while neighboring cells remain undercharged, stressing individual cells on every cycle.
Explaining the long-term stakes of pack management, Clark emphasizes the operational consequences: “Not balancing lithium iron phosphate initially at least is like driving your car and never changing the oil.” While budget battery management systems (BMS) claim automatic protection, relying blindly on emergency shutdowns degrades capacity: “if you just charge your batteries until the BMS cries uncle, all cells are getting damaged every cycle.”
Lithium iron phosphate packs generally rely on two distinct cell equalization strategies: active balancing and passive balancing. Active systems shuttle electrical energy directly from the highest-voltage cell into lower-voltage cells. This internal transfer generates minimal thermal waste and can deliver equalization currents between 1 and 2 amps, bringing mismatched cells into alignment within a few charge cycles.
In contrast, passive balancing dissipates surplus energy as raw heat through internal resistors connected across elevated cells. Because sealed battery enclosures provide limited thermal dissipation, passive bleed circuits operate at modest rates, typically between 50 and 65 milliamps. While slow discharge circuits functioned adequately on legacy 100Ah cells, deploying that same circuitry across modern 300Ah configurations reduces balancing efficacy by two-thirds. On technical projects documented through Emily & Clark’s Adventure, understanding these precise hardware limitations prevents premature equipment failures.
To observe the microscopic electrical behavior hidden behind the front panel, Clark rigs a specialized diagnostic bench. The primary power source is a 60V 5A regulated bench power supply capable of independent voltage clamping and current limiting, paired alongside a secondary 30V 10A unit used for lower-voltage testing. For pack evaluation, a dedicated electronic load provides calibrated discharge tracking in amp-hours and watt-hours, while a bench digital multimeter captures individual cell potentials.
To capture minuscule current movements through the BMS wiring harness, Clark clamps a sensitive current probe to the battery sense wires and routes the signal into a digital oscilloscope. The probe converts milliamps of current into millivolts, allowing the oscilloscope to plot live current draw against time. Clark notes that uncovering the hidden operating rules of the internal circuitry requires methodical observation: “The real trick to balancing these batteries is knowing when they’re actually balancing”.
To initiate the equalization sequence, Clark injects 5 amps from the regulated power supply to elevate cell voltages toward their upper knee. At the initial baseline reading, Cell 5 sits at 3.343 volts as the lowest member of the string, while Cell 9 leads at 3.356 volts. The resulting 13 millivolts delta remains well below the manufacturer’s stated 40 millivolts balancing threshold, keeping internal bleed circuits inactive.
As charging continues at higher voltages, individual cells climb at diverging rates. When Cell 5 reaches 3.383 volts and Cell 9 reaches 3.412 volts, a delta of 29 millivolts forms. Although technical documentation specified a 40 millivolts trigger, the BMS firmware initiates balancing earlier at 29 millivolts. Clark drops the charging current to 350 milliamps to keep the system locked in charging state (“CHG” mode) without accelerating pack voltage toward the high-voltage cutoff threshold of 3.65 volts.
Connecting the current probe across both sense leads for Cell 9 reveals a distinct waveform on the oscilloscope. The signal ledger registers 5.7 millivolts, confirming a localized passive discharge current of 57 milliamps flowing through the bleed resistor.
Monitoring the waveform reveals that the BMS does not apply continuous resistive loading. The circuit engages for approximately two-fifths of the interval (40% duty cycle) before shifting into a slower sequence where it discharges for one-fifth of the time (20% duty cycle). Averaging roughly 30% active time across the cycle, the net effective discharge rate hovers near 20 milliamps. As Cell 10 climbs toward the threshold, the BMS alternates discharge pulses between Cell 9 and Cell 10 in sequential succession.
| Measurement stage | Low cell (Cell 5) | High cell (Cell 9) | Voltage delta | Operating state |
|---|---|---|---|---|
| Initial rest baseline | 3.343 volts | 3.356 volts | 13 millivolts | Quiescent under 40 millivolts |
| High current charging | Rapid rise | Outlier accelerates | Expanding gap | 5 amps power supply feed |
| Balancing onset | 3.383 volts | 3.412 volts | 29 millivolts | 350 milliamps trickle charge |
| Active bleed pulse | Passive hold | 57 milliamps bleed | 5.7 millivolts probe | 30% duty cycle at 20 milliamps |
Because passive bleed circuits dissipate roughly 20 milliamps on average, correcting severe cell imbalances through the automated BMS can require weeks of controlled cycling. Intrepid builders working on accessible rack batteries with removable metal covers can accelerate the process manually.
By taking off watches and metallic jewelry, a technician can touch an external motor braking resistor across high outlier cells to draw 1 to 2 amps of bleed current without generating internal enclosure heat. Alternatively, connecting a bench power supply directly across the lowest cell at 1 to 2 amps lifts low cells to parity: “this can save you days of passive balance time”. Careful voltage monitoring ensures individual cells reach equal capacity safely without exceeding recommended thresholds.
Cells arrive with varying states of charge and capacity headroom. Without initial top balancing, higher outlier cells reach overvoltage limits early and trigger BMS cutoffs, degrading cell life on every cycle.
Active balancing shuttles electrical energy from higher cells to lower cells at 1 to 2 amps with minimal heat. Passive balancing bleeds excess power through resistors as heat at lower rates, typically 50 to 65 milliamps.
The WirenTech BMS requires an active charging state to execute passive balancing. Delivering 350 milliamps keeps the pack in ‘CHG’ mode while preventing cell voltages from climbing too quickly.
Although the manufacturer stated a 40 millivolts delta was necessary, oscilloscope testing confirmed passive balancing initiated at a 29 millivolts delta when Cell 5 was at 3.383 volts and Cell 9 was at 3.412 volts.
Technicians can connect an external motor braking resistor across high cells to safely bleed 1 to 2 amps, or apply a bench power supply directly across the lowest cell at 1 to 2 amps to bring it up to parity.
At WeBoating.com, we profoundly acknowledge the unwavering dedication that Emily & Clark’s Adventure (Clark’s Adventure) invests in crafting each and every video or voyage. Their passion for delivering exceptional ocean content shines through every frame, and it's a labor of love that deserves your attention.
We invite you to watch their captivating videos here and actively engage with their content, including their social media links above. Liking, commenting, and sharing their work goes a long way in fueling their creative fire.
We're also inviting you to explore the gear, sponsorships, and boat partnerships highlighted in the "Lab: Balancing a BIG Battery" video description, or directly on YouTube. By engaging with these offerings or purchasing services and items, you directly support Emily & Clark’s Adventure (Clark’s Adventure), their collaborators, and the brands they're associated with.
To ensure you never miss an offshore update, consider visiting their official YouTube Channel to subscribe, like, and join their community directly.
If you have any feedback, corrections, or additional information about Emily & Clark’s Adventure (Clark’s Adventure) or their videos, please use the comment form below to share your thoughts with us.
Thank you for being a part of our community and supporting the creators we cherish. Your time and support truly matter!
In this video we actually go through the process of Balancing a 16 cell 48V Battery. For our subject we will use the WirenTech 48V 100ah Rack Mount Battery.
Amazon Affiliate Links:
https://amzn.to/3VKYwPS WirenTech 48V 100ah Battery
Not the ones I actually have but the closest by the same company and available now.
https://amzn.to/3VKYwPS 60v 5a Power Supply
https://amzn.to/4jr4SO1 30v 10a Power Supply
https://amzn.to/4zzHvqa Breaking Resistor
https://amzn.to/4Bt9TfN Electronic Load
I just bought this one but it's probably more than you need.
https://amzn.to/4jvwTnP 60v 20a power Supply
Have questions or comments? Leave them below! We do our best to read and answer all comments on our channel.
-----------
LINKS TO PRODUCTS WE LOVE (Affiliate links to things we actually own, use, and recommend. We are almost never paid by companies to endorse products. If we are, we will tell you in the video): https://www.amazon.com/shop/emilyclarksadventure
PLEASE SUBSCRIBE and click the BELL to see new videos every week, and more content like this.
CONNECT & SUPPORT OUR CHANNEL
Patreon: https://www.patreon.com/emilyandclark
PayPal: https://www.paypal.me/emilyandclark
Buy S/V Temptress shirts and swag: https://teespring.com/stores/emily-clarks-sailboat-swag
Check out our favorite products on Amazon: https://www.amazon.com/shop/emilyclarksadventure
#emilyandclark #emilyandclarksadventure #svtemptress
Explore the most recent voyages. Subscribe to the channel to never miss an update!